{"product_id":"pilot-operated-servo-proportional-directional-control-valve-series-d31fp-d41fp-d91fp-d111fp-part-d31fpb61db1vb00","title":"Pilot Operated Servo Proportional Directional Control Valve - Series D31FP \/ D41FP \/ D91FP \/ D111FP Part #: D31FPB61DB1VB00","description":"\u003cp\u003e\u003cspan\u003eThe top-level series of pilot operated servo proportional valves D*1FP is the ultimate choice for highest accuracy in positioning of hydraulic axis and controlling of pressure and velocity. It shows extremly high dynamics combined with high flow. It  The D*1FP series transfers the advantages of the Parker patented Voice Coil Drive (VCD®) to larger frame sizes and thus high flow rates. The high dynamics\/ high precision drive of the pilot valve allows the optimum control of the main spool and results in servo class performance of the complete valves.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe D*1FP series is available in 5 sizes:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• D31FP NG10 (CETOP 05)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• D41FP NG16 (CETOP 07)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• D91FP NG25 (CETOP 08) for port diameter up to 32 mm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• D111FP NG32 (CETOP 10)\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eOptionally available with EtherCAT® interface\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe valves series D*1FP with EtherCAT® interface fulfill  the requirements of modern communication between valve and main control. Due to high data transmission speed and short cycle times, the high dynamics can be also utilized within the fieldbus system.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eRegenerative\/hybrid function (optional)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe innovative integrated regenerative function into the A-line (optional) allows new energy saving circuits for differential cylinders. The hybrid version can be switched between regenerative mode and standard mode at any time.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eMarkets:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Industrial\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Machine tools\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Molding\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFeatures\/Benefits:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Highest dynamics - shorter cycle times and thus higher machine output\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• High flow capacity - optimum efficiency in relation to valve size\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• High-resolution position feedback on main spool - assures stable spool position\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Progressive main spool design (sinus characteristics) - high-resolution position control at small command signals and for high flows where desirable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Defined spool positioning at power-down - optional P-A\/B-T or P-B\/A-T or center position (for overlapped spools)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Digital electronics - permits to store and load valve records\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Optionally with EtherCAT interface, 2x M12x1, connector 4-Pin (Ether-CAT In and EtherCAT Out) - high dynamics can be also utilized within the fieldbus system\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Very robust valve design - lower costs through less downtime\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short delivery time - no warehousing necessary\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eAdditional features\/benefits hybrid version:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Optionally with energy saving A-regeneration or as switchable hybrid version - up to 30 % energy savings through A-return\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Minimal expenditure of assembly due to integrated switching between regenerative and standard circuits\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Complete functionality in one combined unit\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Standard mounting pattern - retrofitting possible\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eApplications:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• General presses\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Die cast\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Injection molding\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Pulp \u0026amp; paper\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eTechnical specifications:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe safety concept works with a safe 4th position at the D1FP pilot valve. This ensures that the main stage is hydraulically balanced at power down and allows to have the main spool spring centered (for overlapped spools) or approximately 10 % spring offset to spool position A or B (for zerolap spools).\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eNote: D81FP NG25 (CETOP 08) for port diameter up to 26 mm is not longer available from Parker, D81FP* with 1:1 replacement by series D91FP*.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"flex\" id=\"section-technical-specifications-toggle\"\u003e\n\u003ch2 class=\"bold nowrap\" id=\"section-technical-specifications-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cspan class=\"expand1-module__GXKRiW__expandIcon1 font-size-xx-large-Blk\" id=\"section-technical-specifications-icon\"\u003e\u003ci class=\"fas fa-minus\"\u003e\u003c\/i\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003csection id=\"section-technical-specifications-content\"\u003e\n\u003cdiv class=\"MuiGrid-root MuiGrid-container mui-1d3bbye\" id=\"pdp-expand1-table-desktop-container\"\u003e\n\u003cdiv class=\"MuiGrid-root MuiGrid-item MuiGrid-grid-xs-12 MuiGrid-grid-lg-12 MuiGrid-grid-xl-12 tableSplit mui-15j76c0\" id=\"pdp-expand1-table-desktop-wrapper\"\u003e\n\u003ctable id=\"pdp-expand1-table-desktop\"\u003e\n\u003ctbody id=\"pdp-expand1-table-desktop-body\"\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-0\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-0\"\u003eFlow Rate:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-0\"\u003e90 L\/MIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-1\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-1\"\u003ePort Connection:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-1\"\u003eNG10 \/ CETOP 05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-2\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-2\"\u003eProduct Series:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-2\"\u003eProportional DC Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-3\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-3\"\u003eMaximum Flow Rate:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-3\"\u003e250 L\/MIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-4\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-4\"\u003ePort Connection:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-4\"\u003eNG10 \/ CETOP 05, NG10 \/ CETOP 05, NG10 \/ CETOP 05, NG10 \/ CETOP 05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-5\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-5\"\u003eOperation Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-5\"\u003ePilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-6\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-6\"\u003eSpool Code:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-6\"\u003eB61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-7\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-7\"\u003eElectronics Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-7\"\u003eOnboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-8\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-8\"\u003eSpool Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-8\"\u003eZerolap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-9\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-9\"\u003ePressure Differential (bar):\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-9\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-10\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-10\"\u003eMaximum Flow Rate:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-10\"\u003e250 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-11\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-11\"\u003eMounting Position:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-11\"\u003ePreferably Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-12\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-12\"\u003eFlow Rate:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-12\"\u003e90 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-13\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-13\"\u003eDefined Spool Position At Power Down:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-13\"\u003eP-B\/A-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-14\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-14\"\u003ePressure Differential:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-14\"\u003e5.0 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-15\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-15\"\u003ePilot Inlet \/ Drain Locations:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-15\"\u003eInternal\/external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-16\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-16\"\u003eMounting Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-16\"\u003eSubplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-17\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-17\"\u003eActuation Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-17\"\u003eVCD®-actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-18\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-18\"\u003eSeal Material:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-18\"\u003eFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-19\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-19\"\u003eSignal Input:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-19\"\u003e0-±10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-20\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-20\"\u003eFor Fluid Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-20\"\u003eHydraulic Oil, Others\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-21\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-21\"\u003eFunction:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-21\"\u003eProportional, 3-Way\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-22\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-22\"\u003eFlow Direction:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-22\"\u003e0-10 V = P-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-23\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-23\"\u003eConnection Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-23\"\u003e6+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-24\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-24\"\u003eMaximum Operating Pressure:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-24\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-25\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-25\"\u003eValve Option:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-25\"\u003eStandard and regenerative valve function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-26\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-26\"\u003eMaximum Ambient Temperature:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-26\"\u003e60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-27\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-27\"\u003eMinimum Ambient Temperature:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-27\"\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-28\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-28\"\u003eMaximum Fluid Temperature:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-28\"\u003e60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-29\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-29\"\u003eMinimum Fluid Temperature:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-29\"\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-30\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-30\"\u003eMaximum Kinematic Viscosity:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-30\"\u003e400 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-31\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-31\"\u003eMinimum Kinematic Viscosity:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-31\"\u003e20 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-32\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-32\"\u003eFilter Efficiency Rating:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-32\"\u003eISO 4406 18\/16\/13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-33\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-33\"\u003eLeak Rate:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-33\"\u003eDepending on Spool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-34\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-34\"\u003eSeal Material:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-34\"\u003eFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-35\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-35\"\u003eMounting Style:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-35\"\u003eDIN 24340, ISO 4401, CETOP RP121, NFPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-36\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-36\"\u003eResponse Time:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-36\"\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-37\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-37\"\u003eHysteresis:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-37\"\u003e\u0026lt; 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-38\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-38\"\u003eIngress Protection Rating:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-38\"\u003eIP65 in accordance with EN 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-39\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-39\"\u003ePower Supply Voltage:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-39\"\u003e24 V Nominal (tolerance range 22 … 30), Electric Shut-off at \u0026lt; 19 V Nominal (tolerance range 22 … 30), Ripple \u0026lt; 5 V % Eff., Surge Free V % Eff.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-40\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-40\"\u003eVibration Resistance:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-40\"\u003e10 Sinus 5...2000 Hz Acc. IEC 60068-2-6, 10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64, 15 Shock Acc. IEC 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-41\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-41\"\u003eBody Material:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-41\"\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-42\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-42\"\u003eWeight:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-42\"\u003e11.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-43\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-43\"\u003eApplication:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-43\"\u003eIndustrial Hydraulic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-44\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-44\"\u003eBrand:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-44\"\u003eParker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-45\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-45\"\u003eTechnology:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-45\"\u003eHydraulics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-46\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-46\"\u003eDivision:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-46\"\u003eIndustrial Systems Division Europe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-47\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-47\"\u003eValve Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-47\"\u003eProportional DC Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-48\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-48\"\u003eMedia:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-48\"\u003eHydraulic Oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-49\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-49\"\u003eMaximum Pilot Pressure:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-49\"\u003e350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-50\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-50\"\u003eMinimum Pilot Pressure:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-50\"\u003e20 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"pdp-expand1-table-desktop-row-51\"\u003e\n\u003ctd class=\"font-size-medium-Blk bold\" id=\"pdp-expand1-table-desktop-label-51\"\u003eVariation of Opening Point:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\" id=\"pdp-expand1-table-desktop-value-51\"\u003eset to 10 % command signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Parker","offers":[{"title":"Default Title","offer_id":52870895206687,"sku":null,"price":15748.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/4776\/2975\/files\/FullSizeRender_98f6324a-9477-4554-b04a-1e4f5ac37eb8.jpg?v=1789152470","url":"https:\/\/www.nraparts.com\/products\/pilot-operated-servo-proportional-directional-control-valve-series-d31fp-d41fp-d91fp-d111fp-part-d31fpb61db1vb00","provider":"NRA PARTS","version":"1.0","type":"link"}