{"product_id":"rkf36250u44a-circuit-breaker-powerpact-r-2500a","title":"RKF36250U44A - Circuit breaker, PowerPacT R, 2500A","description":"\u003cheader\u003e\n\u003ch1 class=\"main-product-info__description svelte-1bjmtua\"\u003eCircuit breaker, PowerPacT R, 2500A, 3 pole, 600VAC, 65kA, busbar, Micrologic 6.0A, 80%\u003c\/h1\u003e\n\u003c\/header\u003e\n\u003cdiv class=\"main-product-info__bottom svelte-1bjmtua\"\u003e\n\u003ch2 class=\"main-product-info__bottom-item main-product-info__bottom-item--product-id svelte-1bjmtua\"\u003eRKF36250U44A\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003ePowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 6.0A trip unit and an LSIG function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 2500A, 3 pole, circuit breaker has an interrupting rating of 65kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLine Rated Current\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e2500 A\u003c\/span\u003eNumber of Poles\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e3P\u003c\/span\u003eControl Type\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eOperating handle\u003c\/span\u003eBreaking capacity code\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eK\u003c\/span\u003eBreaking capacity\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eAIR 65 kA 240 V AC 50\/60 Hz UL 489\u003cbr\u003eAIR 65 kA 480 V AC 50\/60 Hz UL 489\u003cbr\u003eAIR 65 kA 600 V AC 50\/60 Hz UL 489\u003cbr\u003eIcu 85 kA 240 V AC 50\/60 Hz IEC 60947-2\u003cbr\u003eIcu 70 kA 380\/415 V AC 50\/60 Hz IEC 60947-2\u003c\/span\u003e[Ue] rated operational voltage\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e600 V AC 50\/60 Hz UL 489\u003c\/span\u003eNetwork Frequency\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e50\/60 Hz\u003c\/span\u003e[Ics] rated service breaking capacity\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e65 kA 240 V AC 50\/60 Hz IEC 60947-2\u003cbr\u003e55 kA 380\/415 V AC 50\/60 Hz IEC 60947-2\u003c\/span\u003e[Uimp] rated impulse withstand voltage\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e8 kV IEC 60947-2\u003c\/span\u003eTrip unit technology\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eElectronic, ammeter, MicroLogic 6.0 A, LSIG\u003c\/span\u003eContinuous current rating\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e80 %\u003c\/span\u003e[Ui] rated insulation voltage\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e750 V IEC 60947-2\u003c\/span\u003eTrip unit name\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eMicroLogic 6.0 A\u003c\/span\u003eSuitability for isolation\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eYes IEC 60947-2\u003c\/span\u003eUtilisation category\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eCategory A\u003c\/span\u003eAWG gauge\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e3\/0 AWG...750 kcmil aluminium\/copper\u003c\/span\u003eLocal signalling\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eAlarm 1 LED yellow)long-time pick up)\u003cbr\u003e1 LED red)long-time pick up)\u003cbr\u003eTrip causes 1 LED red)\u003cbr\u003e1 LED red)digital ammeter)\u003cbr\u003eGround indicator 1 LED red)\u003cbr\u003ePhase-loading LED green)load balancing)\u003c\/span\u003eMounting mode\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eUnit mount busbar)\u003c\/span\u003eMounting Support\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eBusbar\u003c\/span\u003eElectrical connection\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eBusbar connection, line\u003cbr\u003eBusbar connection, load\u003c\/span\u003eTerminal identifier\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eAL2500RK\u003c\/span\u003eTightening torque\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e548.7 lbf.in (62 N.m) 0.08…0.6 in² (50…400 mm²) (1\/0 AWG...750 kcmil)\u003cbr\u003e548.7 lbf.in (62 N.m) 0.08…0.2 in² (50…150 mm²) (2 x 1\/0 AWG...2 x 300 kcmil)\u003c\/span\u003eNumber of slots\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e2 auxiliary switch OF plug-in)\u003cbr\u003e1 alarm switch SD plug-in)\u003cbr\u003e1 voltage release MN or MX plug-in)\u003c\/span\u003ePower wire stripping length\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e1.4 in (35 mm)\u003c\/span\u003eHeight\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e16.24 in (412.50 mm)\u003c\/span\u003eWidth\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e16.54 in (420.12 mm)\u003c\/span\u003eDepth\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e14.49 in (368.05 mm)\u003c\/span\u003eNet Weight\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e52 lb(US) (23.6 kg)\u003c\/span\u003eQuantity per Set\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e1\u003c\/span\u003eCircuit breaker application\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eHACR rated\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":52872288731423,"sku":null,"price":25000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/4776\/2975\/files\/FullSizeRender_aa6167af-4e9c-4238-9b9f-e1bbb41f6751.jpg?v=1789216125","url":"https:\/\/www.nraparts.com\/products\/rkf36250u44a-circuit-breaker-powerpact-r-2500a","provider":"NRA PARTS","version":"1.0","type":"link"}